More articles from Volume 8, Issue 2, 2019
Effects of “starch:water” ratio on gelatinization of pinhão starch from nine germplasm collections, measured by Differential Scanning Calorimetry
Optimization conditions of UV-C radiation combined with ultrasound-assisted extraction of cherry tomato (Lycopersicon esculentum) lycopene extract
Development and incorporation of nanoemulsions in food
Consumer awareness of the use of food labels in Lagos state, Nigeria
Potentials of African nutmeg (Monodora myristica) as a flavourant in cookie production
Citations
2
Aicha Benbouriche, Hayate Haddadi-Guemghar, Djamila Mehidi-Terki, Lila Boulekbache-Makhlouf, Mostapha Bachir-bey
(2024)
Enrichment of soybean oil with carotenoids from chili paste by-product: enhancement of quality, oxidative stability, and thermo-resistance
Journal of Food Measurement and Characterization, 18(2)
10.1007/s11694-023-02239-2
Adil Khtira, Said Gharby, El Hassan Sakar
(2025)
Physicochemical and sensory induced changes in olive oil (cv ‘Moroccan Picholine’) sourced from various extraction technologies and blended with refined soybean and sunflower oils. A chemometric comparative study
Journal of Food Composition and Analysis, 145()
10.1016/j.jfca.2025.107755Detection of long storage and sunflower adulteration of olive oils using ultra-violet (UV) spectroscopy method
RadiationTechnologyDep. AtomicEnergyCommission of Syria Syria
Abstract
The purpose of the study was to evaluate the effects of Syrian Kaissy olive oil (SKOO) adulteration and long storage periods on the basic quality indices namely, peroxide value (PV), acid value (AV), and absorbance of UV (K232, K270, ∆K and R (K232/K270) values). This study revealed that the quality indexes, including AV, PV, K232, K270 and ∆K values, of all SKOO specimens increased with increasing storage time. It was revealed that the K232, K270 and ∆K values of SKOO specimens stored for 1 and 2 years remained under the limits, established by International Olive Council (IOC), of 2.5, 0.22 and 0.01 units, respectively. While in some cases, the K232, K270 and ∆K values exceeded their respective limits after 8, 9 and 10 years of storage. The index of R (K232/K270) decreased with time of storage.
Keywords
References
Citation
Copyright

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Article metrics
The statements, opinions and data contained in the journal are solely those of the individual authors and contributors and not of the publisher and the editor(s). We stay neutral with regard to jurisdictional claims in published maps and institutional affiliations.